Fired Heater Learning Center

Gas Side Pressure Drop Across Bare Tubes


Gas Side Pressure Drop Across Bare Tubes

The gas side pressure drop may be calculated by any number of methods available today, but the following procedures should give sufficient results for heater design.

Coil Data
Tube outside dia., in: Tube length, ft:
Number of tubes wide: Number of rows:
Transverse pitch of tubes, in: Corbels:
Process Data
Mass flow, lb/hr: Density of gas, lb/ft3:
Pressure Drop, inHO:

Disclaimer:

The formulas and correlations presented herein are all in the public domain and are to be used only as a learning tool. Note that any product, process, or technology in this document may be the subject of other intellectual property rights reserved by sponsors or contributors to this site. This publication is provided as is, without any warranty of any kind, either expressed or implied, including, but not limited to, the implied warranties of fitness for a particular purpose, or non-infringement.

The formulas, correlations, and methods presented herein should not be considered as being recommended by or used by the sponsors of this site. The purpose of this site is educational and the methods may or may not be suitable for actual design of equipment. Only a fired heater design engineer is qualified to decide if a calculation or procedure is correct for an application.